B. Schwagten, L. Jordaens, E. Jessurun, M. Witsenburg, M. Scheffer, T. Szili-Torok, Baffle puncture guided by transoesophageal echocardiography in a patient with dextrocardia and Mustard correction, European Journal of Echocardiography, Volume 10, Issue 1, January 2009, Pages 144–147, https://doi.org/10.1093/ejechocard/jen196
- Share Icon Share
Abstract
A baffle puncture is a challenging procedure but can be safely done using direct visualization of the region of interest. To our knowledge, however, it has never been performed in a patient with dextrocardia. We present a 62-year-old male with dextrocardia, right isomerism, congenitally corrected transposition of the great arteries, persistent left-sided superior and inferior caval veins, atrial septum defect, and pulmonary valve stenosis. The atrial septum defect was surgically closed with a Teflon ® patch, a variant Mustard operation was performed, and also a prosthetic tricuspid valve was implanted. The patient developed multiple episodes of atrial tachycardia leading to acute heart failure on many occasions. An electrophysiological study was undertaken in order to create a bi-atrial electro-anatomical map. Owing to the presence of a prosthetic tricuspid valve, the femoral venous access was used and a baffle puncture was performed using continuous monitoring with fluoroscopy and transoesophageal echocardiography (TEE). The baffle puncture was successful and the tachycardia was ablated in the systemic venous atrium. To our knowledge, we present the very first case report demonstrating a successful baffle puncture in a patient with dextrocardia and Mustard correction. Direct imaging using TEE seems to be a very useful tool for guiding the puncture.
Introduction
Baffle puncture is a challenging procedure but it can be safely performed using direct visualization of the region of interest. 1 , 2 To our knowledge, this procedure has never been performed in a patient with dextrocardia. All equipment used for transseptal puncture is designed for left-sided hearts. Transoesophageal echocardiography (TEE) is a valuable tool to safely guide transseptal puncture in structurally normal atria. 1 , 3 The aim of this case presentation is to demonstrate the usefulness of TEE in structurally and functionally modified hearts.
Case report
A 62-year-old male was presented because of multiple recurrences of atrial tachycardia (AT). At an early age, he was diagnosed with dextrocardia, right isomerism, congenitally corrected transposition of the great arteries, persistent left-sided superior and inferior caval veins, an atrial septum defect (ASD), and pulmonary valve stenosis ( Figure 1 ). At the age of 31, the ASD was closed with a Teflon ® patch and a variant Mustard operation was performed to re-route both left-sided venae cavae to the systemic venous atrium. Fifteen years later, tricuspid valve insufficiency necessitated implantation of a prosthetic atrioventricular valve (St Jude Medical, Minneapolis, MN, USA) in the systemic ventricle ( Figure 1 ). In the last 10 years, the patient has experienced multiple recurrences of AT leading to acute heart failure on many occasions. Pharmacological treatment did not alleviate the symptoms and therefore an electrophysiological study was undertaken in order to determine the origin and possible treatment of the arrhythmia. The study was conducted using femoral venous access because a retrograde arterial approach was impossible, given the presence of a prosthetic tricuspid valve at the base of the pulmonary venous atrium. Under general anaesthesia, the right femoral vein was punctured and a transseptal 8F sheath (SL1, St Jude Medical) was inserted. Using fluoroscopy and TEE for guidance, the tip of the sheath was positioned in the systemic venous atrium adjacent to the baffle ( Figure 2 ). A Brockenbrough needle (St Jude Medical) with a manually modified curve was loaded into the sheath and advanced to within 1 cm of the dilator tip. Using TEE guidance, the tip of the dilator was aimed directly at the baffle in a position where the cavity of the systemic venous atrium could be clearly identified on the contra-lateral side. The baffle was directly approached with the needle under continuous monitoring with fluoroscopy and TEE. A baffle puncture was performed through the Teflon ® patch while injecting radio-opaque contrast through the Brockenbrough needle. As soon as echocardiographic contrast material appeared in the pulmonary venous atrium on TEE, successful trans-baffle puncture was confirmed ( Figure 2 ). The transseptal sheath was then advanced and the dilator and needle were withdrawn. Subsequently, a bi-atrial bipolar activation map ( Figure 3 ) and voltage map could be created using the CARTO TM navigation system (Biosense Webster, Diamond Bar, CA, USA) in combination with the magnetic navigation system (Niobe, Stereotaxis, St. Louis, MO, USA). The voltage map showed multiple channels capable of conducting re-entry tachycardia. The clinical tachycardia was identified and proven to be triggered by a microre-entry circuit in the lower lateral part of the systemic venous atrium. Successful ablation was carried out and sustained tachycardia was no longer inducible. The patient remained haemodynamically stable during the procedure. Transthoracic echocardiography at discharge showed no pericardial effusion.

Schematic of the heart before (left) and after (right) surgical correction. SCV, superior caval vein; Ao, aorta; PA, pulmonary artery; ASD, atrial septum defect; Bfl, baffle; SVA, systemic venous atrium; PVA, pulmonary venous atrium; TVP, prosthetic tricuspid valve; AnLV, anatomical left ventricle; AnRV, anatomical right ventricle; ICV, inferior caval vein; arrow, location of baffle puncture.

( A ) TEE image showing tip of transseptal sheath (arrow) positioned on the baffle. ( B ) TEE image showing appearance of echocardiographic contrast (solid arrow) in the systemic venous atrium before baffle puncture. ( C ) TEE image showing successful trans-baffle puncture confirmed by appearance of echocardiographic contrast material (solid arrow) in the pulmonary venous atrium after injection through the transseptal sheath (dashed arrow). SVA, systemic venous atrium; PVA, pulmonary venous atrium.

CARTO TM activation maps of systemic venous atrium ( A and B ) and pulmonary venous atrium ( C and D ). A microre-entry circuit is identified in the lower lateral part of the systemic venous atrium (red zone, early electrical activation) and successful ablation is carried out in this region (red dots, ablation points).
Discussion
In the early days of percutaneous puncture of the interatrial septum, physicians relied solely on fluoroscopic landmarks to define anatomical boundaries. 4 Subsequently, two-dimensional echocardiography in general and TEE in particular proved to be a useful adjunct to fluoroscopy during transseptal puncture improving its safety and preventing complications, 1 , 3 especially for specific indications. 5 More recently, intracardiac echocardiography (ICE) has emerged as an additional tool to visualize the fossa ovalis and to minimize the risk of life-threatening complications. 6 In the current case, we were confronted with several challenges in order to gain access to the pulmonary venous atrium to create activation and voltage CARTO TM maps. Retrograde mapping of the pulmonary venous atrium through the femoral artery and the aorta was impossible, given the obvious risks associated with passing the prosthetic tricuspid valve. Using the approach via the femoral and the inferior caval vein to reach the pulmonary venous, atrium on the other hand implied puncture of both a Teflon ® patch closing the ASD and the baffle constructed during Mustard surgery. Moreover, the patient also had dextrocardia which complicated the use of standard anatomical landmarks on fluoroscopy. Direct imaging of the cardiac cavities using TEE is proved to be extremely helpful in successfully performing the baffle puncture and avoiding complications. TEE can be used as an alternative to ICE in patients with extremely modified hearts to exclude the presence of thrombotic material in the atria: with the TEE probe already present in the patient at the beginning of the procedure, no additional venous puncture for the ICE is required.
In conclusion, we present the very first report demonstrating a successful baffle puncture in a patient with dextrocardia and status long after Mustard correction. Direct imaging using TEE seems to be a very useful tool for guiding the puncture. We do believe, therefore, that these kind of procedures can be safely done, but only in centres with considerable experience in congenital heart disease, baffle punctures, echocardiography, and electrophysiology.