Abstract

BACKGROUND

Intrauterine devices (IUDs) have been studied for use for emergency contraception for at least 35 years. IUDs are safe and highly effective for emergency contraception and regular contraception, and are extremely cost-effective as an ongoing method. The objective of this study was to evaluate the existing data to estimate the efficacy of IUDs for emergency contraception.

METHODS

The reference list for this study was generated from hand searching the reference lists of relevant articles and our own article archives, and electronic searches of several databases: Medline, Global Health, Clinicaltrials.gov, Popline, Wanfang Data (Chinese) and Weipu Data (Chinese). We included studies published in English or Chinese, with a defined population of women who presented for emergency contraception and were provided with an IUD, and in which the number of pregnancies was ascertained and loss to follow-up was clearly defined. Data from each article were abstracted independently by two reviewers.

RESULTS

The 42 studies (of 274 retrieved) that met our inclusion criteria were conducted in six countries between 1979 and 2011 and included eight different types of IUD and 7034 women. The maximum timeframe from intercourse to insertion of the IUD ranged from 2 days to 10 or more days; the majority of insertions (74% of studies) occurred within 5 days of intercourse. The pregnancy rate (excluding one outlier study) was 0.09%.

CONCLUSIONS

IUDs are a highly effective method of contraception after unprotected intercourse. Because they are safe for the majority of women, highly effective and cost-effective when left in place as ongoing contraception, whenever clinically feasible IUDs should be included in the range of emergency contraception options offered to patients presenting after unprotected intercourse. This review is limited by the fact that the original studies did not provide sufficient data on the delay between intercourse and insertion of the IUD, parity, cycle day of intercourse or IUD type to allow analysis by any of these variables.

Introduction

Unintended pregnancy is a significant problem worldwide. It is estimated that globally at least 36% of pregnancies are unintended (Singh et al., 2009), and in the USA nearly half of pregnancies are unintended (Finer and Zolna, 2011). Emergency contraception offers women an important strategy to prevent pregnancy after intercourse in cases of contraceptive accidents or non-use, or in situations of sexual violence. There are two forms of emergency contraception available today: pills and intrauterine devices (IUDs). The most common medication option is 1.5 mg levonorgestrel, sold in one-pill or two-pill formulations. A newer formulation is 30 mg ulipristal acetate, marketed in the USA as ella® and in much of Europe as ellaOne®. In a few places, such as China, Vietnam and Russia, mifepristone in small doses is available for emergency contraception.

Non-hormonal IUDs (primarily copper-bearing) have been used for emergency contraception for at least 35 years (Lippes et al., 1976). (The levonorgestrel intrauterine system, sold in the USA and Europe under the brand name Mirena®, has not been studied for use for emergency contraception.) Negative experiences with the Dalkon Shield, an IUD available in the 1970s in the USA, led to years of concern about the safety of IUDs and very low levels of IUD use. However, the design of modern IUDs available today is vastly improved, and guidelines from major medical organizations, such as the Centers for Disease Control and Prevention, the World Health Organization, the UK Faculty of Sexual and Reproductive Healthcare and American College of Obstetricians and Gynecologists, note that IUDs are a safe choice for the majority of patients, including young and nulliparous women (World Health Organization, 2009; ACOG Practice Bulletin, 2010; Centers for Disease Control and Prevention, 2010; Faculty of Sexual & Reproductive Healthcare, Clinical Effectiveness Unit, 2011).

One of the major advantages of copper IUDs is that following use for emergency contraception, they can then be left in place to provide at least 10 years of highly effective ongoing contraception. [In the USA ParaGard® is labeled for 10 years of use but there is evidence of efficacy with longer use (Dean and Schwarz, 2011).] IUDs have been shown to be among the most cost-effective methods of contraception (Trussell et al., 2009); the fact that this is a ‘forgettable’ method that does not require action on the part of the user means that there is virtually no scope for user error.

IUDs are experiencing a moderate comeback after years of very low uptake in the USA (Hubacher et al., 2011). In 2008 (the last year for which data are available), 4.9% of American women at risk of pregnancy reported using an IUD (Mosher and Jones, 2010). This is a marked increase from the 0.7% of women at risk of pregnancy choosing IUDs in 1995 (Mosher and Jones, 2010) but is still lower than the use in Europe, where 10% of British women (data from 2009) (Lader, 2009) and 24% of French women (data from 2005) (Moreau et al., 2008) at risk of pregnancy use IUDs. No comparable statistic is available for IUD use among all women at risk of pregnancy in China, but the Chinese National Population and Family Planning Commission reported that 53% of married women using contraception used IUDs in 2009 (National Population and Family Planning Commission, Population and Development Research Center of China, 2010). IUD use is higher in China than in the world overall; a 2005 report noted that 43% of Chinese women using contraception used IUDs, compared with 13% in the rest of the world (Salem, 2006). Guidelines for the use of IUDs for emergency contraception typically recommend inserting the IUD within 5 days of unprotected intercourse (ACOG Practice Bulletin, 2010), although the Centers for Disease Control, the World Health Organization and the UK Faculty of Sexual and Reproductive Healthcare specify that an IUD can be used beyond 5 days, as long as the time of ovulation can be reasonably determined and the insertion occurs no more than 5 days after ovulation (World Health Organization, 2009; Centers for Disease Control and Prevention, 2010; Faculty of Sexual & Reproductive Healthcare, Clinical Effectiveness Unit, 2011). It should be noted that the guidelines around the time of insertion are not related to efficacy or safety but to ensure that the IUD is inserted before the implantation of an embryo (thus ensuring its function as a contraceptive, rather than an early abortifacient).

Materials and Methods

This study is a systematic review designed to provide a current estimate of the efficacy of IUDs used for emergency contraception, based on all of the available published data. The reference list for this study was generated from searching our own archives, references lists of relevant articles and queries of several databases using the following search terms:

MEDLINE: ‘Contraception, Postcoital’ [Mesh] AND ‘Intrauterine Devices’ [Mesh],

Clinicaltrials.gov: ‘intrauterine device’ AND ‘emergency contraception’,

Popline: ‘IUD’ & ‘Emergency Contraception’,

Global Health: ‘intrauterine device’ AND ‘emergency contracept*’ OR ‘postcoit* contracept*’,

Wanfang Data (Chinese): (emergency contraception, intrauterine device),

Weipu Data (Chinese): (emergency contraception, intrauterine device).

This review includes any peer-reviewed study published by August 2011 in English or Chinese, with a defined population of women who presented for emergency contraception and were provided with an IUD, and in which the number of pregnancies was ascertained and loss to follow-up was clearly defined. Chinese data were included because of the tremendous amount of contraceptive research taking place in that country.

Once relevant articles were identified, data from each study were abstracted independently by two reviewers using a common data entry form that captured the language of publication, country in which data were collected, type(s) of IUD used, maximum time from intercourse to IUD insertion, initial study enrollment, efficacy-evaluable population, loss to follow-up and number of treatment failures (pregnancies).

We computed Blyth–Still–Casella exact 95% binomial confidence intervals (CI) for proportions and used either Fisher's Exact Test (for 2 × 2) or Fisher–Freeman–Halton (for R × 2) to test for homogeneity. All calculations were performed in StatXact in Cytel Studio 8 (Cytel Inc., Cambridge, MA, USA).

Results

Our search found 274 articles, and we assessed 48 of these in depth to determine their eligibility for inclusion. Five studies were excluded from our analysis because they did not provide sufficient detail about the loss to follow-up (Bromwich and Parsons, 1982; Hutchinson, 1983; Wright and Thompson, 1986; Friedman and Rowley, 1987; Zhang and Huang, 2005). In addition, one study was published both in English and Chinese, and we included the English version in this analysis (Fan and Zhou, 2001; Zhou and Xiao, 2001). This study included a subject who presented 95 h after unprotected intercourse and was believed to be pregnant as a result of an act of intercourse 16 days prior to insertion of the IUD; this individual was excluded from the analysis. One study was designed to compare the insertion tolerability of the GyneFix IUD versus the Gyne-T380S IUD for emergency contraception but it did report that no pregnancies occurred in the trial, and so we included it in our final dataset (D'Souza et al., 2003). Forty-two studies were included in the final review.

The 42 studies that fit our eligibility criteria and were included in the review ranged in the year of publication from 1979 to 2011 (Table I). Of these, 28 were published in Chinese and 14 in English. The English literature included data collected in China, Egypt, Italy, the Netherlands, USA and the UK. Nearly all of the IUDs were copper-bearing, although a small number of plastic IUDs (the Lippes Loop series) were used in two of the earlier studies (Black et al., 1980; Guillebaud et al., 1983). The majority of studies in our review (31 studies, 74%) followed the current standard protocol of inserting the IUD within 5 days of unprotected intercourse, although one study included 18 (out of 998) insertions beyond 5 days (Zhou and Xiao, 2001), three studies provided insertions up to 7 days after intercourse (Gottardi et al., 1979; Lippes et al., 1979; Luerti et al., 1986), one allowed insertions up to 10 days (Black et al., 1980) and one included 24 insertions (out of 64) at 10 or more days post-coitus (Goldstuck, 1983). One study did not specify the time to insertion at all (D'Souza et al., 2003). The studies did not include sufficient information on the delay between intercourse and insertion of the IUD to enable us to analyze the data by delay.

Table I

Studies included in review of the efficacy of IUDs for emergency contraception over 35 years, in order of publication.

Study Country IUD type Max. time to insertion (days) Enrolled (nEfficacy population (nPregnancies (nPregnancy rate (%) (95% CI)a 
Gottardi et al. (1979)b Italy Cu T-200 60 60 0 (0–6.0) 
Lippes et al. (1979)b USA Cu T-200, Cu 7 299 299 0 (0–1.2) 
Tyrer (1980)b USA Cu 7 80 80 0 (0–4.5) 
Black et al. (1980)b UK Cu 7, Lippes Loop D 10 191 176 0 (0–2.1) 
Van Santen and Haspels (1981)b Netherlands MLCu-250, Cu 7, Cu T-200 55 55 0 (0–6.5) 
Goldstuck (1983)b UK Cu 7, Cu 7 Mini, Cu T, MLCu 250, MLCu 250 short 10+ 71 64 0 (0–5.6) 
Guillebaud et al. (1983)b UK Cu 7, Lippes Loop 87 87 0 (0–4.2) 
Gottardi et al. (1986)b Italy Cu T-200, Cu 7, Cu 7 Mini, MLCu-250 98 91 0 (0–4.0) 
Luerti et al. (1986)b Italy MLCu-250, Cu 7, Cu T 117 102 0 (0–3.6) 
Askalani et al. (1987)b Egypt Cu T-200 200 200 2.0 (0.5–5.0) 
Yang et al. (1997) China ML Cu-375 SL 30 30 0 (0–11.6) 
Li et al. (1999) China ML Cu-375 SL 101 101 0 (0–3.6) 
Zhang et al. (1999) China ML Cu-375 SL 100 100 0 (0–3.6) 
Lu (2000) China Copper IUD (unspecified) 28 28 0 (0–12.3) 
Tian (2000) China Copper IUD (unspecified) 80 80 0 (0–4.5) 
Li et al. (2001) China Cu T-380A 94 94 0 (0–3.8) 
Zhao et al. (2001) China ML Cu-375 SL 98 98 1.0 (0.0–5.6) 
Zhou and Xiao (2001)b China ML Cu-375 SL 5+ 1013 998 0.1 (0.0–0.6) 
Liu and Chen (2002a,bChina ML Cu-375 SL 80 80 1.2 (0.0–6.8) 
Liu and Chen (2002a,bChina Copper IUD (unspecified) 95 95 0 (0–3.8) 
Sun et al. (2003) China GyneFix 86 86 0 (0–4.2) 
D'Souza et al. (2003)b UK GyneFix, Gyne-T 380S Unspecified 173 169 0 (0–2.2) 
Tang et al. (2003) China ML Cu-375 SL 98 98 1.0 (0.0–5.6) 
Wang and Jiang (2003) China Copper IUD (unspecified) 86 86 0 (0–4.2) 
Zhao and Wang (2004) China Cu T-220 108 108 0 (0–3.4) 
Hou (2005) China Nova T-380 100 100 0 (0–3.6) 
Li et al. (2005) China ML Cu-375 SL 150 150 0 (0–2.4) 
Wen (2005) China Cu T-380A 218 218 0.5 (0.0–2.5) 
Wang et al. (2006) China Cu T-380A 200 200 0 (0–1.8) 
Dong and Wu (2007) China Copper IUD (unspecified) 87 87 0 (0–4.2) 
Sheng and Zhang (2007) China Copper IUD (unspecified) 27 27 0 (0–12.8) 
Song et al. (2007) China ML Cu-375 SL 180 180 0 (0–2.0) 
Yang et al. (2008) China Cu T-380A 100 100 0 (0–3.6) 
Hong (2008) China GyneFix 100 100 0 (0–3.6) 
Ma et al. (2008) China MCu 26 26 0 (0–13.2) 
Yang et al. (2008) China ML Cu-375 SL 86 86 0 (0–4.2) 
He (2009) China Copper IUD (unspecified), ML Cu-375 SL 108 108 0 (0–3.3) 
Hong (2009) China Copper IUD (unspecified) 70 70 0 (0–5.1) 
Liu et al. (2010) China ML Cu-375 SL 162 162 0.6 (0.0–3.4) 
Turok et al. (2010)b USA Cu T-380A 23 22 0 (0–15.4) 
Wang (2010) China Copper IUD (unspecified) 40 40 0 (0–8.8) 
Wu et al. (2010)b China Cu T-380A 1963 1893 0 (0–0.2) 
Study Country IUD type Max. time to insertion (days) Enrolled (nEfficacy population (nPregnancies (nPregnancy rate (%) (95% CI)a 
Gottardi et al. (1979)b Italy Cu T-200 60 60 0 (0–6.0) 
Lippes et al. (1979)b USA Cu T-200, Cu 7 299 299 0 (0–1.2) 
Tyrer (1980)b USA Cu 7 80 80 0 (0–4.5) 
Black et al. (1980)b UK Cu 7, Lippes Loop D 10 191 176 0 (0–2.1) 
Van Santen and Haspels (1981)b Netherlands MLCu-250, Cu 7, Cu T-200 55 55 0 (0–6.5) 
Goldstuck (1983)b UK Cu 7, Cu 7 Mini, Cu T, MLCu 250, MLCu 250 short 10+ 71 64 0 (0–5.6) 
Guillebaud et al. (1983)b UK Cu 7, Lippes Loop 87 87 0 (0–4.2) 
Gottardi et al. (1986)b Italy Cu T-200, Cu 7, Cu 7 Mini, MLCu-250 98 91 0 (0–4.0) 
Luerti et al. (1986)b Italy MLCu-250, Cu 7, Cu T 117 102 0 (0–3.6) 
Askalani et al. (1987)b Egypt Cu T-200 200 200 2.0 (0.5–5.0) 
Yang et al. (1997) China ML Cu-375 SL 30 30 0 (0–11.6) 
Li et al. (1999) China ML Cu-375 SL 101 101 0 (0–3.6) 
Zhang et al. (1999) China ML Cu-375 SL 100 100 0 (0–3.6) 
Lu (2000) China Copper IUD (unspecified) 28 28 0 (0–12.3) 
Tian (2000) China Copper IUD (unspecified) 80 80 0 (0–4.5) 
Li et al. (2001) China Cu T-380A 94 94 0 (0–3.8) 
Zhao et al. (2001) China ML Cu-375 SL 98 98 1.0 (0.0–5.6) 
Zhou and Xiao (2001)b China ML Cu-375 SL 5+ 1013 998 0.1 (0.0–0.6) 
Liu and Chen (2002a,bChina ML Cu-375 SL 80 80 1.2 (0.0–6.8) 
Liu and Chen (2002a,bChina Copper IUD (unspecified) 95 95 0 (0–3.8) 
Sun et al. (2003) China GyneFix 86 86 0 (0–4.2) 
D'Souza et al. (2003)b UK GyneFix, Gyne-T 380S Unspecified 173 169 0 (0–2.2) 
Tang et al. (2003) China ML Cu-375 SL 98 98 1.0 (0.0–5.6) 
Wang and Jiang (2003) China Copper IUD (unspecified) 86 86 0 (0–4.2) 
Zhao and Wang (2004) China Cu T-220 108 108 0 (0–3.4) 
Hou (2005) China Nova T-380 100 100 0 (0–3.6) 
Li et al. (2005) China ML Cu-375 SL 150 150 0 (0–2.4) 
Wen (2005) China Cu T-380A 218 218 0.5 (0.0–2.5) 
Wang et al. (2006) China Cu T-380A 200 200 0 (0–1.8) 
Dong and Wu (2007) China Copper IUD (unspecified) 87 87 0 (0–4.2) 
Sheng and Zhang (2007) China Copper IUD (unspecified) 27 27 0 (0–12.8) 
Song et al. (2007) China ML Cu-375 SL 180 180 0 (0–2.0) 
Yang et al. (2008) China Cu T-380A 100 100 0 (0–3.6) 
Hong (2008) China GyneFix 100 100 0 (0–3.6) 
Ma et al. (2008) China MCu 26 26 0 (0–13.2) 
Yang et al. (2008) China ML Cu-375 SL 86 86 0 (0–4.2) 
He (2009) China Copper IUD (unspecified), ML Cu-375 SL 108 108 0 (0–3.3) 
Hong (2009) China Copper IUD (unspecified) 70 70 0 (0–5.1) 
Liu et al. (2010) China ML Cu-375 SL 162 162 0.6 (0.0–3.4) 
Turok et al. (2010)b USA Cu T-380A 23 22 0 (0–15.4) 
Wang (2010) China Copper IUD (unspecified) 40 40 0 (0–8.8) 
Wu et al. (2010)b China Cu T-380A 1963 1893 0 (0–0.2) 

aWhere the pregnancy rate is zero, a one-sided 97.5% CI is calculated. Otherwise, a 95% exact binomial CI is calculated.

bIndicates publication in English; otherwise, studies were published in Chinese.

Among 7034 post-coital IUD insertions, there were 10 pregnancies, for an overall failure rate of 0.14% (95% CI = 0.08–0.25%) (Table II). Six pregnancies occurred among 5629 subjects in the studies conducted in China (failure rate = 0.11%; 95% CI = 0.05–0.23%) and the remaining four pregnancies occurred among 200 subjects in one study conducted in Egypt (Askalani et al., 1987). Strikingly, this study is the only RCT with a non-treatment arm for a contraceptive product that we are aware of. Three hundred women who had engaged in unprotected intercourse around the time of ovulation (and so had a relatively high probability of pregnancy) were randomized to either post-coital insertion of a Cu T-200 or no treatment. The pregnancy rates were 2% among the treatment group and 22% in the expectant management group. The failure rate in the treatment arm of this study is surprisingly high, and significantly higher than the rate in all other countries combined (P = 0.0001); in contrast, the results among the five countries excluding Egypt are homogeneous (P= 1). If the true failure rate in Egypt were the same as in the other five countries (0.000878), then the chance of observing four or more pregnancies is vanishingly small, ∼1 in 30 000 (P= 0.00004). This high failure rate can possibly be explained by the fact that women were specifically selected if they had had intercourse around the time of ovulation; in any event Egypt is a clear outlier. If the unusual results from the Egypt study were excluded, the overall failure rate would be 0.09% (95% CI = 0.04–0.19%); this is our preferred estimate.

Table II

Failure rates for IUD use as emergency contraception, by country.

Country Population Pregnancies Rate (%) Exact 95% CI (%)
 
China 5629 0.11 0.05 0.23 
UK 496 0.00 0.00 0.70 
USA 401 0.00 0.00 0.85 
Italy 253 0.00 0.00 1.38 
Egypt 200 2.00 0.69 5.03 
The Netherlands 55 0.00 0.00 5.93 
Total 7034 10 0.14 0.08 0.25 
Total excluding Egypt 6834 0.09 0.04 0.19 
Country Population Pregnancies Rate (%) Exact 95% CI (%)
 
China 5629 0.11 0.05 0.23 
UK 496 0.00 0.00 0.70 
USA 401 0.00 0.00 0.85 
Italy 253 0.00 0.00 1.38 
Egypt 200 2.00 0.69 5.03 
The Netherlands 55 0.00 0.00 5.93 
Total 7034 10 0.14 0.08 0.25 
Total excluding Egypt 6834 0.09 0.04 0.19 

Discussion

Our data suggest that IUDs are a highly effective method of emergency contraception, with a failure rate of less than one per thousand. The copper IUD is by far the most effective emergency contraceptive option, followed by mid-dose mifepristone (25–50 mg) or ulipristal acetate (failure rate ∼1.4%) and then levonorgestrel (failure rate ∼2–3%) (Cheng et al., 2008; Glasier et al., 2010).

Data from two randomized trials of the ulipristal acetate and levonorgestrel regimens suggest that the efficacy of levonorgestrel declines sharply as BMI increases. Statistical models indicate that, among women with a BMI of 26 kg/m2 or higher presenting after unprotected intercourse, levonorgestrel is no more effective than no treatment. Ulipristal acetate appears to retain its efficacy at higher BMI levels but is no more effective than no treatment at a BMI of 35 or higher (Glasier et al., 2011). There is no clinical concern about the loss of effectiveness of the IUD with an increase in BMI; therefore, an IUD would be a particularly good choice for obese women presenting after unprotected sex.

Several recent studies exploring the awareness of and the interest in IUDs among women seeking emergency contraception identified barriers to a greater use of IUDs including cost, waiting time (patients are not always able to get an IUD the day that they present for emergency contraception), low levels of awareness and understanding among patients and lack of participation among providers (Schwarz et al., 2009; Bharadwaj et al., 2011; Turok et al., 2011; Wright et al., 2012). Two of these studies found that around 12% of women presenting for emergency contraception or walk-in pregnancy testing would consider an IUD as an alternative to emergency contraceptive pills (Schwarz et al., 2009; Turok et al., 2011); this finding indicates the considerable potential to increase IUD uptake among women who have recently had unprotected sex. A study of contraceptive providers in CA, USA, showed that 85% of clinicians never recommended the IUD for emergency contraception, and 93% require at least two visits for an IUD insertion (Harper et al., 2012).

Our review has several limitations. The initial intention of this study was to assess the efficacy of IUDs for emergency contraception by the day of insertion (how many days had elapsed between unprotected intercourse and insertion of the IUD), but the studies generally did not include sufficient detail about the day of insertion among the efficacy-evaluable population. Therefore, our analysis groups all cases together, regardless of the length of delay between intercourse and insertion of the IUD. Similarly, we are unable to provide estimates of the efficacy by parity, individual pregnancy risk (the cycle day on which intercourse occurred) and IUD type, as most studies did not provide detailed information on these variables. Finally, as in any review, it is possible that studies may have been unintentionally excluded owing to incomplete search results. We were not able to include publications in languages other than English and Chinese; it is a limitation that relevant studies in other languages were omitted, as these might have added strength to these results. However, we believe that English and Chinese journals include the majority of publications on this topic.

Conclusions

Despite the limitations of the original data, this study contributes to the literature and to clinical practice by providing the most comprehensive review to date of the efficacy of IUDs used for emergency contraception. These results provide clear evidence that IUDs are a highly effective method of emergency contraception, as 99.86% of users overall did not become pregnant after unprotected intercourse when an IUD was inserted post-coitally. When we exclude the data from the Egyptian study (which does not represent the typical clinical scenario because the investigators intentionally selected women who were at a greater risk of pregnancy), the failure rate is 0.09%.

The cost, clinical protocols and lack of awareness among both patients and providers are barriers to a greater uptake of IUDs for emergency contraception. Increasing the use of IUDs for emergency contraception is an important strategy for reducing an individual woman's chance of becoming pregnant after unprotected intercourse. In addition, if left in place for ongoing contraception, copper IUDs provide highly effective contraception for at least 10 years, and can contribute to decreasing unintended pregnancy rates over the long term. Therefore, we conclude that IUDs should be routinely included as an emergency contraceptive option whenever clinically feasible and appropriate.

Authors' roles

K.C. conducted the English literature search, abstracted data from the English literature and drafted the article. H.Z. conducted the Chinese literature search, abstracted data from the Chinese literature and provided comments on the manuscript. N.G. abstracted data from the English literature and provided comments on the manuscript. L.C. abstracted data from the Chinese literature and provided comments on the manuscript. J.T. oversaw the quantitative analysis and provided comments on the manuscript.

Funding

Support for Dr Trussell's work was provided by the Eunice Kennedy Shriver National Institute of Child Health and Development, Grant 2R24HD047879. No other external support was provided for this study.

Conflict of interest

None declared.

References

ACOG Practice Bulletin
Clinical management guidelines for obstetrician-gynecologists. Number 112, emergency contraception
Obstet Gynecol
 , 
2010
, vol. 
115
 (pg. 
1100
-
1108
)
Askalani
AH
Al-Senity
AM
Al-Agizy
HM
Salem
HI
Al-Masry
GI
El-Sadek
SM
Evaluation of copper T-200 as a post-coital contraceptive
Egypt Obstet Gynecol
 , 
1987
, vol. 
13
 (pg. 
63
-
66
)
Bharadwaj
P
Saxton
J
Mann
S
Jungmann
E
Stephenson
J
What influences young women to choose between the emergency contraceptive pill and an intrauterine device? A qualitative study
Eur J Contracept Reprod Health Care
 , 
2011
, vol. 
16
 (pg. 
201
-
209
)
Black
TRL
Goldstuck
ND
Spence
A
Post-coital intrauterine device insertion—a further evaluation
Contraception
 , 
1980
, vol. 
22
 (pg. 
653
-
658
)
Bromwich
PD
Parsons
AD
The establishment of a postcoital contraception service
Br J Fam Plan
 , 
1982
, vol. 
8
 (pg. 
16
-
19
)
Centers for Disease Control and Prevention
U.S. Medical Eligibility Criteria for Contraceptive Use, 2010
2010
, vol. 
Vol. 59
 
MMWR
(pg. 
1
-
85
Cheng
L
Guelmenzoglu
AM
Piaggio
G
Ezcurra
E
Van
LPFA
Interventions for emergency contraception
Cochrane Database Syst Rev
 , 
2008
, vol. 
2
 
Dean
G
Schwarz
EB
Hatcher
RA
Trussell
J
Nelson
A
Cates
W
Stewart
F
Kowal
D
Policar
M
Intrauterine contraceptives
Contraceptive Technology
 , 
2011
New York, NY
Ardent Media
Dong
SZ
Wu
SH
Mifepristone, levonorgestrel and IUD for emergency contraception: a 268-case control study
J Chin Mod Gyn Ob
 , 
2007
, vol. 
4
 (pg. 
127
-
129
Chinese
D'Souza
R
Masters
T
Bounds
W
Guillebaud
J
Randomised controlled trial assessing the acceptability of GyneFix versus Gyne-T380S for emergency contraception
J Fam Plan Reprod H
 , 
2003
, vol. 
29
 (pg. 
23
-
29
)
Faculty of Sexual & Reproductive Healthcare, Clinical Effectiveness Unit
Clinical Guidance on Emergency Contraception 2011
 
Fan
HM
Zhou
LY
Emergency contraception with Multiload Cu-375SL IUD: a multicentre clinical trial
J Reprod Med
 , 
2001
, vol. 
10
 (pg. 
70
-
77
Chinese
Finer
LB
Zolna
MR
Unintended pregnancy in the United States: incidence and disparities 2006
Contraception
 , 
2011
, vol. 
84
 (pg. 
478
-
85
)
Friedman
EHI
Rowley
DEM
Post-coital contraception—a two-year evaluation of a service
Br J Fam Plan
 , 
1987
, vol. 
13
 (pg. 
139
-
144
)
Glasier
AF
Cameron
S
Fine
P
Logan
S
Casale
W
Van Horn
J
Sogor
L
Blithe
D
Scherrer
B
Mathe
H
, et al.  . 
Ulipristal acetate versus levonorgestrel for emergency contraception: a randomised non-inferiority trial and meta-analysis
Lancet
 , 
2010
, vol. 
375
 (pg. 
555
-
562
)
Glasier
A
Cameron
ST
Blithe
D
Scherrer
B
Mathe
H
Levy
D
Gainer
E
Ulmann
A
Can we identify women at risk of pregnancy despite using emergency contraception? Data from randomized trials of ulipristal acetate and levonorgestrel
Contraception
 , 
2011
, vol. 
84
 (pg. 
363
-
367
)
Goldstuck
ND
Delayed postcoital IUD insertion
Contracept Deliv Syst
 , 
1983
, vol. 
4
 (pg. 
293
-
296
)
Gottardi
G
Marzi
M
Pozzi
S
Postcoital estrogen or IUD?
IPPF Euro Reg Bull
 , 
1979
, vol. 
8
 (pg. 
7
-
8
)
Gottardi
G
Spreafico
A
de Orchi
L
The postcoital IUD as an effective continuing contraceptive method
Contraception
 , 
1986
, vol. 
34
 (pg. 
549
-
558
)
Guillebaud
J
Kubba
A
Rowlands
S
White
J
Elder
MG
Post-coital contraception with danazol, compared with an ethinyloestradiol-norgestrel combination or insertion of an intra-uterine device
J Obstet Gynaecol
 , 
1983
, vol. 
3
 
Suppl. 2
(pg. 
S64
-
S68
)
Harper
CC
Speidel
JJ
Drey
EA
Trussell
J
Blum
M
Darney
PD
Copper intrauterine device for emergency contraception: clinical practice among contraceptive providers
Obstet Gynecol
 , 
2012
, vol. 
119
 (pg. 
220
-
226
)
He
YM
Comparison of mifepristone and copper IUD for emergency contraception
Shanxi Med J
 , 
2009
, vol. 
38
 pg. 
703
  
Chinese
Hong
SZ
GyneFix for emergency contraception
Contemp Med
 , 
2008
, vol. 
145
 (pg. 
36
-
37
Chinese
Hong
CP
A clinical study of emergency contraception methods: levonorgestrel and IUD
Chin Health Care Nutr
 , 
2009
, vol. 
18
 (pg. 
91
-
92
Chinese
Hou
XL
Clinical analysis of NovaT-380 IUD as emergency contraception
Chin Gen Prac
 , 
2005
, vol. 
8
 (pg. 
292
-
930
Chinese
Hubacher
D
Finer
LB
Espey
E
Renewed interest in intrauterine contraception in the United States: evidence and explanation
Contraception
 , 
2011
, vol. 
83
 (pg. 
291
-
294
)
Hutchinson
F
Grahame
H
Experience at London brook advisory centres
Postcoital Contraception: Methods, Services and Prospects
 , 
1983
London
Pregnancy Advisory Service
(pg. 
40
-
42
)
Lader
D
Contraception and Sexual Health, 2008/09
2009
, vol. 
41
  
Opinions Survey Report
Li
HZ
Wang
P
Li
SZ
Wu
BS
Zuo
WL
Clinical trial of the efficacy of the copper IUD for emergency contraception
Chin J Imp Birth Outcomes Child Dev
 , 
1999
, vol. 
10
 (pg. 
157
-
159
Chinese
Li
H
Tong
Q
Huang
XJ
Shu
LZ
TCu-380A IUD for emergency contraception (with a one-year follow-up available)
J Tibet Med
 , 
2001
, vol. 
22
 (pg. 
47
-
49
Chinese
Li
FX
Qian
XJ
Wu
WP
A case control study of active IUD and mifepristone for emergency contraception
Prac Med J
 , 
2005
, vol. 
21
 (pg. 
2313
-
2314
Chinese
Lippes
J
Malik
T
Tatum
HJ
The postcoital copper-T
Adv Plann Parent
 , 
1976
, vol. 
11
 (pg. 
24
-
29
)
Lippes
J
Tatum
H
Maulik
D
Zielezny
M
Postcoital copper IUDs
Adv Plann Parent
 , 
1979
, vol. 
14
 (pg. 
87
-
94
)
Liu
XJ
Multiload for emergency contraception
Chin Prac Med
 , 
2010
, vol. 
30
 (pg. 
135
-
136
Chinese
Liu
LP
Chen
AX
Comparison of emergency contraception with IUD and mifepristone
J Changzhi Med Col
 , 
2002
, vol. 
16
 (pg. 
198
-
199
Chinese
Liu
Y
Chen
XX
IUD insertion and mifepristone for emergency contraception
J Qiqihar Med Col
 , 
2002
, vol. 
23
 (pg. 
890
-
891
Chinese
Lu
J
Clinical application of the copper IUD for emergency contraception
Chin J Mod Med
 , 
2000
, vol. 
10
 pg. 
48
  
Chinese
Luerti
M
Tonta
A
Ferla
P
Molla
R
Santini
F
Post-coital contraception by estrogen progestagen combination or IUD insertion
Contraception
 , 
1986
, vol. 
33
 (pg. 
61
-
68
)
Ma
XY
Zhang
ZH
Sun
CY
A report on 26 cases of MLCu IUD as emergency contraception
Mod Prev Med
 , 
2008
, vol. 
35
 (pg. 
4372
-
4373
Chinese
Moreau
C
Lydie
N
Warzwaski
J
Bajos
N
Beck
F
Guilbert
P
Gautier
A
Activite sexuelle, infections sexuellement transmissibles, contraception
Barometre Sante 2005
 , 
2008
Saint Denis
IPNES
(pg. 
329
-
353
)
Mosher
WD
Jones
J
Use of contraception in the United States: 1982–2008
Vital Health Stat
 , 
2010
, vol. 
29
 (pg. 
1
-
44
)
National Population and Family Planning Commission, Population and Development Research Center of China
Nationwide distribution of contraceptive methods in married reproductive age women
Pop Fam Plan Data
 , 
2010
 
China Population Publishing Houseinese 194
Salem
RM
New attention to the IUD: expanding women's contraceptive options to meet their needs
Popul Rep B
 , 
2006
, vol. 
7
 (pg. 
1
-
26
)
Schwarz
EB
Kavanaugh
M
Douglas
E
Dubowitz
T
Creinin
MD
Interest in intrauterine contraception among seekers of emergency contraception and pregnancy testing
Obstet Gynecol
 , 
2009
, vol. 
113
 (pg. 
833
-
839
)
Sheng
QY
Zhang
XL
A clinical study to compare mifepristone and IUD for emergency contraception
Chin Comm Doc
 , 
2007
, vol. 
9
 pg. 
38
  
Chinese
Singh
S
Wulf
D
Hussain
R
Bankole
A
Sedgh
G
Abortion Worldwide: A Decade of Uneven Progress
2009
 
Song
CH
Wang
Y
Chen
P
Wang
D
Lu
WH
A case-control study of mifepristone and IUD for emergency contraception
Chin Med Factory Mine
 , 
2007
, vol. 
20
 (pg. 
630
-
631
Chinese
Sun
Q
Dong
J
Sun
Y
GyneFix IUD for emergency contraception
J Shandong Med
 , 
2003
, vol. 
43
 pg. 
65
  
Chinese
Tang
LR
Nan
XP
Wu
MH
Fan
HM
A clinical study of Multiload 375-SL for emergency contraception
Beijing Med J
 , 
2003
, vol. 
25
 (pg. 
137
-
138
Chinese
Tian
QH
Clinical trial of mifepristone and IUD for emergency contraception
J Henan Med Col for Staff and Workers
 , 
2000
, vol. 
12
 pg. 
51
  
Chinese
Trussell
J
Lalla
AM
Doan
QV
Reyes
E
Pinto
L
Gricar
J
Cost effectiveness of contraceptives in the United States
Contraception
 , 
2009
, vol. 
79
 (pg. 
5
-
14
)
Turok
DK
Gurtcheff
SE
Handley
E
Simonsen
SE
Sok
C
Murphy
P
A pilot study of the Copper T380A IUD and oral levonorgestrel for emergency contraception
Contraception
 , 
2010
, vol. 
82
 (pg. 
520
-
525
)
Turok
DK
Gurtcheff
SE
Handley
E
Simonsen
SE
Sok
C
A survey of women obtaining emergency contraception: are they interested in using the copper IUD?
Contraception
 , 
2011
, vol. 
83
 (pg. 
441
-
446
)
Tyrer
LB
The copper-7 and postcoital contraception
Adv Plann Parent
 , 
1980
, vol. 
15
 (pg. 
111
-
117
)
Van Santen
MR
Haspels
AA
Interception by post-coital IUD insertion
Contracept Deliv Syst
 , 
1981
, vol. 
2
 (pg. 
189
-
200
)
Wang
XH
Copper IUD for emergency contraception: a case control study
Health Must-Read Mag
 , 
2010
, vol. 
6
 pg. 
144
  
Chinese
Wang
JH
Jiang
L
An 86-case analysis of copper IUD for emergency contraception
Ningxia Med J
 , 
2003
, vol. 
25
 pg. 
353
  
Chinese
Wang
CP
Liu
Y
Chang
YF
Shao
WQ
Feasibility of IUD and low-dose mifepristone for emergency contraception
J Fertility
 , 
2006
, vol. 
15
 (pg. 
271
-
273
Chinese
Wen
CL
Study of the efficacy of TCu380A for emergency contraception
Prac Diag Treat J
 , 
2005
, vol. 
19
 (pg. 
731
-
732
Chinese
World Health Organization
Medical Eligibility Criteria for Contraceptive Use
 , 
2009
 
Wright
DW
Thompson
PM
Monitoring a post-coital contraception service
Br J Fam Plan
 , 
1986
, vol. 
12
 (pg. 
88
-
91
)
Wright
R
Frost
C
Turok
DK
A qualitative exploration of emergency contraception users' willingness to select the copper IUD
Contraception
 , 
2012
, vol. 
85
 (pg. 
32
-
35
)
Wu
S
Godfrey
EM
Wojdyla
D
Dong
J
Cong
J
Wang
C
von Hertzen
H
Copper T380A intrauterine device for emergency contraception: a prospective, multicentre, cohort clinical trial
BJOG-Int J Obstet Gynaecol
 , 
2010
, vol. 
117
 (pg. 
1205
-
1210
)
Yang
MH
A clinical study of effect of the multiload as emergency contraception
Guide Chin Med
 , 
2008
, vol. 
6
 (pg. 
20
-
22
Chinese
Yang
Y
Zhang
XM
Wei
DY
Yi
SJ
Clinical study of mifepristone, A-nordrin and intrauterine device used for emergency contraception
J Reprod Med
 , 
1997
, vol. 
6
 (pg. 
171
-
173
Chinese
Yang
D
Lei
ZW
Li
M
He
Z
Xu
LL
Clinical evaluation of emergency contraception with TCu380A IUD
Sichuan Med J
 , 
2008
, vol. 
29
 (pg. 
1
-
2
Chinese
Zhang
LP
Huang
Q
Women's acceptance of IUDs as emergency contraception
Coll J Wannan Med Sch
 , 
2005
, vol. 
16
 (pg. 
117
-
118
Chinese
Zhang
LJ
Jing
XP
Wen
LJ
A case-control study of mifepristone and the copper IUD for emergency contraception
Chin J Obstet Gynecol
 , 
1999
, vol. 
34
 (pg. 
569
-
570
Chinese
Zhao
YH
Wang
XL
Copper IUD for emergency contraception
Chin J Med Res Appl
 , 
2004
, vol. 
2
 (pg. 
31
-
32
Chinese
Zhao
H
Tang
LR
Wu
MH
Cheng
H
Clinical research on mifepristone and IUD for emergency contraception
J Cap Univ Med Sci
 , 
2001
, vol. 
22
 (pg. 
273
-
274
Chinese
Zhou
L
Xiao
B
Emergency contraception with multiload Cu-375SL IUD: a multicenter clinical trial
Contraception
 , 
2001
, vol. 
64
 (pg. 
107
-
112
)