-
Views
-
Cite
Cite
Bhavesh H Patel, Bhanubhai N Suhagia, Madhabhai M Patel, Jignesh R Patel, Simultaneous Estimation of Pantoprazole and Domperidone in Pure Powder and a Pharmaceutical Formulation by High-Perfomance Liquid Chromatography and High-Performance Thin-Layer Chromatography Methods, Journal of AOAC INTERNATIONAL, Volume 90, Issue 1, 1 January 2007, Pages 142–146, https://doi.org/10.1093/jaoac/90.1.142
- Share Icon Share
Abstract
This paper describes validated high-performance liquid chromatography (HPLC) and high-performance thin-layer chromatography (HPTLC) methods for the simultaneous estimation of pantoprazole (PANT) and domperidone (DOM) in pure powder and capsule formulations. The HPLC separation was achieved on a Phenomenex C18 column (250 mm id, 4.6 mm, 5 μm) using 0.01 M, 6.5 pH ammonium acetate buffer-methanol-acetonitrile (30 + 40 + 30, v/v/v, pH 7.20) as the mobile phase at a flow rate of 1.0 mL/min at ambient temperature. The HPTLC separation was achieved on an aluminum-backed layer of silica gel 60F254 using ethyl acetatemethanol (60 + 40, v/v) as the mobile phase. Quantification was achieved with ultraviolet (UV) detection at 287 nm over the concentration range 400-4000 and 300-3000 ng/mL with mean recovery of 99.35 ± 0.80 and 99.08 ± 0.57% for PANT and DOM, respectively (HPLC method). Quantification was achieved with UV detection at 287 nm over the concentration range 80-240 and 60-180 ng/spot with mean recovery of 98.40 ± 0.67 and 98.75 ± 0.71% for PANT and DOM, respectively (HPTLC method). These methods are simple, precise, and sensitive, and they are applicable for the simultaneous determination of PANT and DOM in pure powder and capsule formulations.