-
Views
-
Cite
Cite
Yan Xing, Yulia Bronstein, Merrick I. Ross, Robert L. Askew, Jeffrey E. Lee, Jeffrey E. Gershenwald, Richard Royal, Janice N. Cormier, Contemporary Diagnostic Imaging Modalities for the Staging and Surveillance of Melanoma Patients: a Meta-analysis, JNCI: Journal of the National Cancer Institute, Volume 103, Issue 2, 19 January 2011, Pages 129–142, https://doi.org/10.1093/jnci/djq455
- Share Icon Share
Abstract
Meta-analyses were performed to examine the utility of ultrasonography, computed tomography (CT), positron emission tomography (PET), and a combination of both (PET-CT) for the staging and surveillance of melanoma patients.
Patient-level data from 74 studies containing 10 528 patients (between January 1, 1990, and June, 30, 2009) were used to derive characteristics of the diagnostic tests used. Meta-analyses were conducted by use of Bayesian bivariate binomial models to estimate sensitivity and specificity. Diagnostic odds ratios [ie, true-positive results/false-negative results)/(false-positive results/true-negative results)] and their 95% credible intervals (CrIs) and positive predictive values were used as indicators of test performance.
Among the four imaging methods examined for the staging of regional lymph nodes, ultrasonography had the highest sensitivity (60%, 95% CrI = 33% to 83%), specificity (97%, 95% CrI = 88% to 99%), and diagnostic odds ratio (42, 95% CrI = 8.08 to 249.8). For staging of distant metastases, PET-CT had the highest sensitivity (80%, 95% CrI = 53% to 93%), specificity (87%, 95% CrI = 54% to 97%), and diagnostic odds ratio (25, 95% CrI = 3.58 to 198.7). Similar trends were observed for melanoma surveillance of lymph node involvement, with ultrasonography having the highest sensitivity (96%, 95% CrI = 85% to 99%), specificity (99%, 95% CrI = 95% to 100%), and diagnostic odds ratio (1675, 95% CrI = 226.6 to 15,920). For distant metastases, PET-CT had the highest sensitivity (86%, 95% CrI = 76% to 93%), specificity (91%, 95% CrI = 79% to 97%), and diagnostic odds ratio (67, 95% CrI = 20.42 to 229.7). Positive predictive values were likewise highest for ultrasonography in lymph node staging and for PET-CT in detecting distant metastases.
Among the compared modalities, ultrasonography was superior for detecting lymph node metastases, and PET-CT was superior for the detection of distant metastases in both the staging and surveillance of melanoma patients.
- positron-emission tomography
- positive predictive value
- ultrasonography
- computed tomography
- costa rica
- diagnostic techniques and procedures
- melanoma
- diagnosis
- diagnostic imaging
- lymph nodes
- lymph node metastasis
- computed tomography/positron emission tomography imaging
- surveillance, medical
- metastasis, distant
- false-positive results
- false-negative results
- true-negative result
- true-positive result