-
PDF
- Split View
-
Views
-
Cite
Cite
C González Díaz, H Carrascosa, G M Muñoz Caro, M Á Satorre, Y-J Chen, Density and infrared band strength of interstellar carbon monoxide (CO) ice analogues, Monthly Notices of the Royal Astronomical Society, Volume 517, Issue 4, December 2022, Pages 5744–5755, https://doi.org/10.1093/mnras/stac3122
- Share Icon Share
ABSTRACT
The motivation to study experimentally CO ice under mimicked interstellar conditions is supported by the large CO gas abundances and ubiquitous presence of CO in icy grain mantles. Upon irradiation in its pure ice form, this highly stable species presents a limited ion and photon-induced chemistry, and an efficient non-thermal desorption. Using infrared spectroscopy, single laser interference, and quadrupole mass spectrometry during CO ice deposition, the CO ice density was estimated as a function of deposition temperature. Only minor variations in the density were found. The proposed methodology can be used to obtain the density of other ice components at various deposition temperatures provided that this value of the density is known for one of these temperatures, which is typically the temperature corresponding to the crystalline form. The apparent tendency of the CO ice density to decrease at deposition temperatures below 14 K is in line with recently published colorimetric measurements. This work allowed us to revisit the value of the infrared band strength needed for calculation of the CO ice column density in infrared observations, 8.7 × 10−18 cm molecule−1 at 20 K deposition temperature.
1 INTRODUCTION
Carbon monoxide (CO) gas abundances in dense clouds suggest that 90 per cent of the CO molecules leave the gas phase along the line of sight, and over 99 per cent of them should deplete in the core nucleus (Caselli et al. 1999) due to CO freeze out on to dust grains forming ice mantles (e.g. Pontoppidan et al. 2008). Protostar formation heats the surrounding environment and triggers the thermal desorption of ice mantles (Cazaux et al. 2003). CO is considered to be one, if not the most, abundant species on the top ice layer covering inter- and circumstellar dust grains observed towards the coldest regions. Along with CO and likely other volatile molecules of weak dipole moment, this top ice layer is expected to host species with no dipole moment like N2 (Pontoppidan et al. 2008). This ice phase is thus weakly bound by intermolecular van der Waals forces and offers the possibility to desorb molecules by direct cosmic ray impact (Huang et al. 2020; Dartois et al. 2021), X-rays (Ciaravella et al. 2012, 2016) in protoplanetary discs, or ultraviolet (UV) photons (Öberg et al. 2007; Öberg, van Dishoeck & Linnartz 2009; Muñoz Caro et al. 2010; Fayolle et al. 2011; Chen et al. 2014; Cruz-Díaz et al. 2014) generated by the interaction of cosmic rays with H2 present in dense clouds (Prasad & Tarafdar 1983; Cecchi-Pestellini & Aiello 1992; Shen et al. 2004). In the case of multicomponent ice mixtures, the UV-photodesorption yield of CO is severely reduced in the presence of H2O, also N2 neighbours reduce the efficiency of CO UV-photodesorption (Bertin et al. 2012, 2013; Carrascosa et al. 2019). But photodesorption of CO molecules during UV-irradiation of pure CO ice is not much hindered by the presence of other species in the ice. This is due to the low efficiency in the formation of CO photoproducts during irradiation.
The CO photodesorption yield reaches its highest value when this ice is deposited at low temperatures (down to 7 K, the lowest temperature studied experimentally) and decreases gradually at higher deposition temperatures (Öberg et al. 2007; Öberg et al. 2009; Muñoz Caro et al. 2010, 2016; Sie et al. 2022). The explanation for this phenomenon motivated further research. It was found that the columnar structure of CO ice samples, grown at incidence angles larger than 45°, increases the effective ice surface exposed to UV photons and therefore the photodesorption efficiency (González Díaz et al. 2019), but ice surface effects cannot account for the large variations observed in the photodesorption of CO ice samples deposited at different temperatures (Muñoz Caro et al. 2016). Absorption band shifts of CO ice in the UV and IR ranges only occurred at deposition temperatures above 20 K (Lasne et al. 2015; Muñoz Caro et al. 2016), suggesting that CO ice grown at lower temperatures is amorphous below 20 K in our experiments, and therefore, the decreasing photodesorption yield is not related to a transition from amorphous to crystalline ice, instead it might be associated to a different degree of molecular disorder in CO ice samples, depending on their deposition temperature. Photon energy transfer via Wannier-Mott excitons between the first photoexcited molecule in the ice and a molecule on the ice surface capable to desorb was proposed (Chen et al. 2017; McCoustra & Thrower 2018). Molecular disorder seems to enhance this energy transfer between neighbour molecules. The colour temperature variations measured at different deposition temperatures could also be the result of molecular disorder (Carrascosa et al. 2021). Urso et al. (2016), Cazaux et al. (2017), and Carrascosa et al. (2021) did not find significant changes in the desorption behaviour or the colour temperature of pure CO ice during controlled warm-up, which points to a low value of the diffusion in the ice. Finally, Sie et al. (2022) investigated the CO photodesorption yield dependence on ice thickness.
CO ice density could also provide information about the ice structure dependence on deposition temperature. Luna et al. (2022) report the density of CO ice grown at different temperatures using laser interferometry and a microbalance. Here we use a different method to measure the density of CO ice grown at different temperatures and confirm the results of Luna et al. (2022); this method can be used by other authors to estimate the ice density with the use of infrared spectroscopy, laser interferometry, and a quadrupole mass spectrometer.
The most commonly used IR band strength value of CO ice, 1.1 × 10−17 cm molecule−1, dates from 1975 (Jiang, Person & Brown 1975) and relies on much older references: They adopted a density of 1.028 g cm−3 for pure solid CO in the α-phase (crystalline ice) at 30 K (Vegard 1930), which is significantly higher than the one reported by Roux et al. (1980), 0.80 g cm−3 at 20 K, and Luna et al. (2022), 0.88 g cm−3 at 20 K. Jiang et al. (1975) used a value of the refractive index, n = 1.35, that is also higher than those reported by Roux et al. (1980), n = 1.27 at 20 K, and Luna et al. (2022), n = 1.30 at 20 K. Finally, Jiang et al. (1975) employed an ice thickness deposition rate between 0.5 and 2 μm min−1, this rate is very high compared to the ones used in modern setups devoted to astrochemistry and might affect the ice structure; this issue is studied in this article. For comparison, the highest deposition rate used in this work was around 30 nm min−1, which corresponds to a CO pressure of 10−6 mbar during deposition. The IR band strength is a fundamental parameter needed to calculate the ice column density in the line of sight of the observations, it is therefore revisited in this paper.
2 EXPERIMENTAL
2.1 Experimental setup
Experiments were carried out using the Interstellar Astrochemistry Chamber (ISAC), described in more detail in Muñoz Caro et al. (2010). ISAC is an ultra-high vacuum (UHV) chamber with a base pressure of 4 × 10−11 mbar designed to simulate the conditions present in the interstellar medium (ISM), regarding temperature, pressure, and radiation field. A closed-cycle He cryostat allows to cool down the tip of the cold finger to 8 K, where a sample holder with an MgF2 window acting as the substrate for ice deposition is located. In the experiments reported in this work the lowest achievable temperature was 11 K because the radiation shield surrounding the sample holder would block the laser signal and was removed for this reason. Temperature is controlled by a Lakeshore temperature controller 331, with a precision of 0.1 K. The gas line system in ISAC allows us to introduce gas species with a controlled composition, determined by quadrupole mass spectrometry (QMS, Pfeiffer Vacuum, Prisma QMS 200). Fig. 1 shows a scheme of the ISAC setup. The gas line is connected to the main chamber through a leak valve. During deposition, this valve is opened and the gas is directed to the cold substrate via a deposition tube. The end of this tube is about 3 cm away from the substrate. The sample holder can be rotated at any desired angle. Infrared spectra were recorded during deposition, irradiation (if it is the case) and temperature programmed desorption (TPD) using Fourier transform infrared spectroscopy (FTIR) in transmittance mode with a Bruker Vertex 70 at working spectral resolution of 2 cm−1. Laser interferometry at 632.8 nm was implemented in ISAC to measure changes in the ice thickness for this work. A He-Ne red laser (5.0 mW, 500:1 Polarization. Longitudinal mode frequency is ∼ 438 MHz with the spectral bandwidth being approximately 1400 MHz, Model: N-LHP-151) and a Silicon Photodiode Power Sensor to measure the optical power of the laser light (model S120C) are placed with an angle of ∼6°. The distance of 40 cm between the laser and the substrate allows us to separate the laser reflection coming from the viewport of ISAC and the laser reflection arriving from the cold substrate where the ice sample is grown.

Intersection of ISAC at the level of the ice sample. Its multiple measurement components and sensors are shown, including the laser. QMS stands for quadrupole mass spectrometer, while FTIR is the Fourier transform infrared spectrometer with the FTIR source on one viewport and the FTIR detector on the opposite side. The UV spectrometer is located opposite to the vacuum-UV lamp.
In a typical experiment, once the deposition temperature was reached, CO was introduced in the main chamber for 30 min by opening the leak valve of gas line 2 in Fig. 1 and the desired deposition pressure of 1 × 10−6 mbar was reached. Additional experiments were performed using a lower CO pressure in the 10−8–10−6 mbar range and longer deposition times, to explore the effect of deposition pressure in the ice density. The laser was turned on for more than 30 min before starting the ice deposition, to ensure the stability of the signal. Infrared spectra at 45° incidence of the beam relative to the substrate were taken every 60 s during deposition of the ice. The laser was pointing to the substrate and laser interference was measured. Purity of the ice samples was >99.9 per cent, as inferred from QMS data taken during deposition of the ice. Warm-up of the samples after deposition was carried out at 0.1 K min−1 until desorption ended near 30 K, and IR measurements were performed every 60 s.
Fig. 2 shows the main parameters monitored during the experiments using various instruments. The temperature of the ice sample was measured using a silicon diode sensor placed just below the ice sample and attached to the sample holder. Pressure was monitored in the main chamber of ISAC using a Bayard-Alpert gauge located about 23 cm below the plane where deposition takes place. The relative sensitivity of Bayard-Alpert gauge to CO is 1.0, the same as N2 (Rumble 2022). Because CO was the only gas species deposited on the cold substrate, the pressure profile coincides with the |$\frac{m}{z} = 28$| signal measured by QMS. Laser interference was measured continuously, creating an interference pattern during deposition of the ice, and a new interference during TPD. In this configuration, the deposited ice film is homogeneous according to ballistic simulations, in particular the formation of a columnar structure in the ice becomes only important at larger deposition angles, i.e. above 45° (González Díaz et al. 2019). Finally, the column density of the ice was obtained from IR spectroscopy using the areas that result from integration of the absorption bands, this is discussed in Section 2.3. The lower sensitivity of our FTIR and the time lapses between IR spectra may account for the delayed onset of thermal desorption of the ice compared to the other techniques presented in Fig. 2. From this figure, the end of thermal desorption is observed simultaneously by IR spectroscopy and laser interferometry. The pressure gauge and the QMS still observe an increase of CO molecules in the gas due to desorption from CO ice layers accreted on the cold finger outside the MgF2 substrate window. This effect is enhanced by the absence of a radiation shield in our laser interferometry experiments.

Main parameters controlled during experiments as a function of time. From top to bottom: temperature, pressure in the main chamber, |$\frac{m}{z} = 28$| intensity from QMS data, laser intensity, integrated infrared absorbance from the CO ice band centred at 2138 cm−1 that is proportional to its column density.
2.2 Ice thickness estimation from laser interference
The ice thickness was measured using single laser interference. One wave is reflected from the ice surface and one transmitted through the ice and then reflected from the surface of the cold substrate used for ice deposition. The reflection of both waves, shown in Fig. 3, creates an interference pattern as the result of ice thickness increase during deposition. If the deposition rate is constant, this interference forms a periodic pattern that allows estimation of the ice thickness, e.g. Hecht (2017).

Sketch of the thin film interference principle, with the two reflections shown.
2.3 Infrared band strength of CO ice
3 RESULTS
3.1 Interference of substrate window used for ice deposition

Expansion coefficient α of MgF2 obtained from data reported in the literature. Data points are represented as blue empty squares. The solid black line was obtained from interpolation of these data points.

Estimated thickness d (in mm) of the 2 mm-thick MgF2 window, used as the substrate for CO ice deposition, during TPD experiments.
A similar calculation was performed for a KBr window substrate. For this material, the literature data (Meincke & Graham 1965; Feldman et al. 1975) only allowed to calculate the thickness expansion above 90 K, an increase of 50 K in temperature corresponds to about 4 μm expansion of the 2 mm-thick KBr substrate.
For this reason, we selected the MgF2 window as the substrate for laser interferometry measurements of ice samples.
3.2 Density measurements
Tdep . | ΔP . | |$\frac{\Delta P(T) \cdot t(T)}{d(T)}$| . | ρ(T) . | |$\frac{\Delta P(T) \cdot t(T)}{d(T)}$| . | ρ(T) . | |$\frac{(\Delta P(T) \cdot t(T))_{TPD}}{(\Delta P(T) \cdot t(T))_{\rm dep}}$| . |
---|---|---|---|---|---|---|
. | . | . | . | n = 1.3 . | n = 1.3 . | . |
K . | mbar . | mbar s m−1 . | g cm−3 . | mbar s m−1 . | g cm−3 . | . |
11 | 1 × 10−6 | 1465.30 | 0.831 | 1488.23 | 0.844 | 1.16 |
11 | 1 × 10−6 | 1487.03 | 0.843 | 1510.31 | 0.857 | 1.15 |
11 | 2 × 10−7 | 1530.94 | 0.868 | 1554.90 | 0.882 | 1.21 |
11 | 4 × 10−7 | 1640.57 | 0.931 | 1666.24 | 0.945 | 1.19 |
11 | 5 × 10−7 | 1507.72 | 0.855 | 1531.32 | 0.869 | 1.19 |
11 | 5 × 10−7 | 1517.92 | 0.861 | 1541.68 | 0.874 | 1.17 |
11 | 8 × 10−7 | 1505.57 | 0.854 | 1529.12 | 0.867 | 1.19 |
11 | 1 × 10−8 | 1538.55 | 0.873 | 1562.63 | 0.886 | 1.30 |
12 | 1 × 10−6 | 1487.15 | 0.844 | 1510.42 | 0.856 | – |
13 | 1 × 10−6 | 1525.01 | 0.865 | 1548.88 | 0.879 | 1.17 |
14 | 1 × 10−6 | 1519.76 | 0.862 | 1523.28 | 0.864 | 1.17 |
15 | 1 × 10−6 | 1568.16 | 0.889 | 1570.58 | 0.891 | 1.16 |
15 | 1 × 10−6 | 1532.77 | 0.869 | 1535.14 | 0.871 | 1.17 |
16 | 1 × 10−6 | 1554.15 | 0.882 | 1555.35 | 0.882 | 1.16 |
17 | 1 × 10−6 | 1517.99 | 0.861 | 1520.33 | 0.862 | 1.18 |
17 | 1 × 10−6 | 1518.01 | 0.861 | 1520.36 | 0.862 | 1.16 |
18 | 1 × 10−6 | 1553.39 | 0.881 | 1563.02 | 0.887 | 1.16 |
18 | 1 × 10−6 | 1528.33 | 0.867 | 1537.81 | 0.872 | 1.17 |
19 | 1 × 10−6 | 1544.58 | 0.876 | 1544.58 | 0.876 | 1.15 |
20 | 1 × 10−6 | 1544.41 | 0.876 | 1544.41 | 0.876 | 1.16 |
20 | 1 × 10−6 | 1542.38 | 0.875 | 1542.38 | 0.875 | 1.16 |
21 | 1 × 10−6 | 1526.56 | 0.866 | 1526.56 | 0.866 | 1.17 |
22 | 1 × 10−6 | 1537.54 | 0.872 | 1537.54 | 0.872 | 1.16 |
23 | 1 × 10−6 | 1543.98 | 0.876 | 1560.21 | 0.885 | 1.14 |
Tdep . | ΔP . | |$\frac{\Delta P(T) \cdot t(T)}{d(T)}$| . | ρ(T) . | |$\frac{\Delta P(T) \cdot t(T)}{d(T)}$| . | ρ(T) . | |$\frac{(\Delta P(T) \cdot t(T))_{TPD}}{(\Delta P(T) \cdot t(T))_{\rm dep}}$| . |
---|---|---|---|---|---|---|
. | . | . | . | n = 1.3 . | n = 1.3 . | . |
K . | mbar . | mbar s m−1 . | g cm−3 . | mbar s m−1 . | g cm−3 . | . |
11 | 1 × 10−6 | 1465.30 | 0.831 | 1488.23 | 0.844 | 1.16 |
11 | 1 × 10−6 | 1487.03 | 0.843 | 1510.31 | 0.857 | 1.15 |
11 | 2 × 10−7 | 1530.94 | 0.868 | 1554.90 | 0.882 | 1.21 |
11 | 4 × 10−7 | 1640.57 | 0.931 | 1666.24 | 0.945 | 1.19 |
11 | 5 × 10−7 | 1507.72 | 0.855 | 1531.32 | 0.869 | 1.19 |
11 | 5 × 10−7 | 1517.92 | 0.861 | 1541.68 | 0.874 | 1.17 |
11 | 8 × 10−7 | 1505.57 | 0.854 | 1529.12 | 0.867 | 1.19 |
11 | 1 × 10−8 | 1538.55 | 0.873 | 1562.63 | 0.886 | 1.30 |
12 | 1 × 10−6 | 1487.15 | 0.844 | 1510.42 | 0.856 | – |
13 | 1 × 10−6 | 1525.01 | 0.865 | 1548.88 | 0.879 | 1.17 |
14 | 1 × 10−6 | 1519.76 | 0.862 | 1523.28 | 0.864 | 1.17 |
15 | 1 × 10−6 | 1568.16 | 0.889 | 1570.58 | 0.891 | 1.16 |
15 | 1 × 10−6 | 1532.77 | 0.869 | 1535.14 | 0.871 | 1.17 |
16 | 1 × 10−6 | 1554.15 | 0.882 | 1555.35 | 0.882 | 1.16 |
17 | 1 × 10−6 | 1517.99 | 0.861 | 1520.33 | 0.862 | 1.18 |
17 | 1 × 10−6 | 1518.01 | 0.861 | 1520.36 | 0.862 | 1.16 |
18 | 1 × 10−6 | 1553.39 | 0.881 | 1563.02 | 0.887 | 1.16 |
18 | 1 × 10−6 | 1528.33 | 0.867 | 1537.81 | 0.872 | 1.17 |
19 | 1 × 10−6 | 1544.58 | 0.876 | 1544.58 | 0.876 | 1.15 |
20 | 1 × 10−6 | 1544.41 | 0.876 | 1544.41 | 0.876 | 1.16 |
20 | 1 × 10−6 | 1542.38 | 0.875 | 1542.38 | 0.875 | 1.16 |
21 | 1 × 10−6 | 1526.56 | 0.866 | 1526.56 | 0.866 | 1.17 |
22 | 1 × 10−6 | 1537.54 | 0.872 | 1537.54 | 0.872 | 1.16 |
23 | 1 × 10−6 | 1543.98 | 0.876 | 1560.21 | 0.885 | 1.14 |
Tdep . | ΔP . | |$\frac{\Delta P(T) \cdot t(T)}{d(T)}$| . | ρ(T) . | |$\frac{\Delta P(T) \cdot t(T)}{d(T)}$| . | ρ(T) . | |$\frac{(\Delta P(T) \cdot t(T))_{TPD}}{(\Delta P(T) \cdot t(T))_{\rm dep}}$| . |
---|---|---|---|---|---|---|
. | . | . | . | n = 1.3 . | n = 1.3 . | . |
K . | mbar . | mbar s m−1 . | g cm−3 . | mbar s m−1 . | g cm−3 . | . |
11 | 1 × 10−6 | 1465.30 | 0.831 | 1488.23 | 0.844 | 1.16 |
11 | 1 × 10−6 | 1487.03 | 0.843 | 1510.31 | 0.857 | 1.15 |
11 | 2 × 10−7 | 1530.94 | 0.868 | 1554.90 | 0.882 | 1.21 |
11 | 4 × 10−7 | 1640.57 | 0.931 | 1666.24 | 0.945 | 1.19 |
11 | 5 × 10−7 | 1507.72 | 0.855 | 1531.32 | 0.869 | 1.19 |
11 | 5 × 10−7 | 1517.92 | 0.861 | 1541.68 | 0.874 | 1.17 |
11 | 8 × 10−7 | 1505.57 | 0.854 | 1529.12 | 0.867 | 1.19 |
11 | 1 × 10−8 | 1538.55 | 0.873 | 1562.63 | 0.886 | 1.30 |
12 | 1 × 10−6 | 1487.15 | 0.844 | 1510.42 | 0.856 | – |
13 | 1 × 10−6 | 1525.01 | 0.865 | 1548.88 | 0.879 | 1.17 |
14 | 1 × 10−6 | 1519.76 | 0.862 | 1523.28 | 0.864 | 1.17 |
15 | 1 × 10−6 | 1568.16 | 0.889 | 1570.58 | 0.891 | 1.16 |
15 | 1 × 10−6 | 1532.77 | 0.869 | 1535.14 | 0.871 | 1.17 |
16 | 1 × 10−6 | 1554.15 | 0.882 | 1555.35 | 0.882 | 1.16 |
17 | 1 × 10−6 | 1517.99 | 0.861 | 1520.33 | 0.862 | 1.18 |
17 | 1 × 10−6 | 1518.01 | 0.861 | 1520.36 | 0.862 | 1.16 |
18 | 1 × 10−6 | 1553.39 | 0.881 | 1563.02 | 0.887 | 1.16 |
18 | 1 × 10−6 | 1528.33 | 0.867 | 1537.81 | 0.872 | 1.17 |
19 | 1 × 10−6 | 1544.58 | 0.876 | 1544.58 | 0.876 | 1.15 |
20 | 1 × 10−6 | 1544.41 | 0.876 | 1544.41 | 0.876 | 1.16 |
20 | 1 × 10−6 | 1542.38 | 0.875 | 1542.38 | 0.875 | 1.16 |
21 | 1 × 10−6 | 1526.56 | 0.866 | 1526.56 | 0.866 | 1.17 |
22 | 1 × 10−6 | 1537.54 | 0.872 | 1537.54 | 0.872 | 1.16 |
23 | 1 × 10−6 | 1543.98 | 0.876 | 1560.21 | 0.885 | 1.14 |
Tdep . | ΔP . | |$\frac{\Delta P(T) \cdot t(T)}{d(T)}$| . | ρ(T) . | |$\frac{\Delta P(T) \cdot t(T)}{d(T)}$| . | ρ(T) . | |$\frac{(\Delta P(T) \cdot t(T))_{TPD}}{(\Delta P(T) \cdot t(T))_{\rm dep}}$| . |
---|---|---|---|---|---|---|
. | . | . | . | n = 1.3 . | n = 1.3 . | . |
K . | mbar . | mbar s m−1 . | g cm−3 . | mbar s m−1 . | g cm−3 . | . |
11 | 1 × 10−6 | 1465.30 | 0.831 | 1488.23 | 0.844 | 1.16 |
11 | 1 × 10−6 | 1487.03 | 0.843 | 1510.31 | 0.857 | 1.15 |
11 | 2 × 10−7 | 1530.94 | 0.868 | 1554.90 | 0.882 | 1.21 |
11 | 4 × 10−7 | 1640.57 | 0.931 | 1666.24 | 0.945 | 1.19 |
11 | 5 × 10−7 | 1507.72 | 0.855 | 1531.32 | 0.869 | 1.19 |
11 | 5 × 10−7 | 1517.92 | 0.861 | 1541.68 | 0.874 | 1.17 |
11 | 8 × 10−7 | 1505.57 | 0.854 | 1529.12 | 0.867 | 1.19 |
11 | 1 × 10−8 | 1538.55 | 0.873 | 1562.63 | 0.886 | 1.30 |
12 | 1 × 10−6 | 1487.15 | 0.844 | 1510.42 | 0.856 | – |
13 | 1 × 10−6 | 1525.01 | 0.865 | 1548.88 | 0.879 | 1.17 |
14 | 1 × 10−6 | 1519.76 | 0.862 | 1523.28 | 0.864 | 1.17 |
15 | 1 × 10−6 | 1568.16 | 0.889 | 1570.58 | 0.891 | 1.16 |
15 | 1 × 10−6 | 1532.77 | 0.869 | 1535.14 | 0.871 | 1.17 |
16 | 1 × 10−6 | 1554.15 | 0.882 | 1555.35 | 0.882 | 1.16 |
17 | 1 × 10−6 | 1517.99 | 0.861 | 1520.33 | 0.862 | 1.18 |
17 | 1 × 10−6 | 1518.01 | 0.861 | 1520.36 | 0.862 | 1.16 |
18 | 1 × 10−6 | 1553.39 | 0.881 | 1563.02 | 0.887 | 1.16 |
18 | 1 × 10−6 | 1528.33 | 0.867 | 1537.81 | 0.872 | 1.17 |
19 | 1 × 10−6 | 1544.58 | 0.876 | 1544.58 | 0.876 | 1.15 |
20 | 1 × 10−6 | 1544.41 | 0.876 | 1544.41 | 0.876 | 1.16 |
20 | 1 × 10−6 | 1542.38 | 0.875 | 1542.38 | 0.875 | 1.16 |
21 | 1 × 10−6 | 1526.56 | 0.866 | 1526.56 | 0.866 | 1.17 |
22 | 1 × 10−6 | 1537.54 | 0.872 | 1537.54 | 0.872 | 1.16 |
23 | 1 × 10−6 | 1543.98 | 0.876 | 1560.21 | 0.885 | 1.14 |
Fig. 6 presents the estimated density of CO ice deposited at 11 K in various experiments performed at different deposition pressure of CO gas. Error bars correspond to the standard deviation calculated from at least two repeated experiments performed at the same conditions. According to this data, a relatively small increase in the CO ice density is observed when the deposition was done at the lower CO pressures.

Density of CO ice deposited at different CO gas pressure. The black squares correspond to the density estimated using a refractive index value of n = 1.28 from Luna et al. (2022) for 13 K, a temperature close to our deposition temperature of 11 K in these experiments. The red squares correspond to density values using n = 1.30 as the typical value of crystalline CO ice grown above 20 K in Luna et al. (2022).
Fig. 7 shows the CO ice volumetric densities estimated for the various deposition temperatures from 11 to 23 K. As already mentioned in Section 2.1, the reported experiments were performed with no radiation shield and therefore 11 K, instead of the usual 8 K in our ISAC setup, was the lowest achievable temperature. Error bars correspond to the standard deviation calculated from at least two repeated experiments performed at the same conditions. A good agreement is found with the recent values reported in Luna et al. (2022), which is reproduced here for comparison (blue stars). Above 14 K, the CO ice density is stabilized around 0.88 g cm−3. A decrease in the density can be appreciated below 13 K deposition temperature.

Density of CO ice deposited at different temperatures. The black squares correspond to densities estimated using refractive index values at the different deposition temperatures provided in Luna et al. (2022), n = n(T). The red squares correspond to densities estimated using a constant value of the refractive index, n = 1.3 for all deposition temperatures. For comparison, the density values reported in Luna et al. (2022) are represented as blue stars. In all the experiments, the CO pressure during deposition was 1 × 10−6 mbar.
3.3 Estimation of infrared band strength of CO ice

Infrared spectra of CO ice deposited at 20 K as a function of deposition time. Left-hand inlet: The red trace is the fit of the integrated absorbance (‘Area (cm−1)’ in this figure) as a function of deposition time. The goodness of fit is R > 0.99. Right-hand inlet: The values of the integrated absorption at various deposition times are provided.

Relatively short ice deposition at 20 K to estimate the infrared band strength using d value from laser interference shown in figure (black trace). The red trace is the fit of the second half of the cycle from 410 to 637 s to obtain the ice deposition rate in nm/min. The red crosses indicate the position of the minimum and maximum points of the cycle. The blue trace corresponds to the integrated band area as a function of time during deposition of the ice, presented in Fig. 8.
4 CONCLUSIONS
We found a good agreement between the volumetric ice densities obtained by Luna et al. (2022) at different deposition temperatures of CO and those reported in this work. The different density values reported here for varying CO pressure during deposition indicate that this parameter must also be considered when data among different laboratories are compared. This new methodology can thus be used for calculation of the ice density at different ice accretion temperatures before the onset of thermal desorption, provided that this value is known for one specific temperature. This method presents some advantages: (i) only one laser, instead of two, is required, to measure the ice thickness, (ii) the microbalance is replaced by the more commonly used FTIR spectrometer for estimation of the ice mass, this allows estimation of the IR band strength of the ice and monitoring of possible structural ice changes, and (iii) the pressure of the vacuum chamber is usually recorded during the experiments, or alternatively the mass spectrum of the deposited species, both techniques are routinely used in experimental astrochemistry setups.
The CO ice band strength provided in this work, |$\mathcal {A}(\rm CO)$| = (8.7 ± 0.5) × 10−18 cm molecule−1, leads to column densities a factor of about 1.3 larger than the most frequently used literature value from Jiang et al. (1975), |$\mathcal {A}(\rm CO)$| = 1.1 × 10−17 cm molecule−1. The updated CO band strength in Bouilloud et al. (2015) considered a refractive index of n = 1.25 and density of ρ = 0.8 g cm−3, it is very similar to the value of Jiang et al. (1975). As explained in Section 3.3, our lower value of |$\mathcal {A}(\rm CO)$| was obtained from our measurements of ice thickness and IR absorbance, and the values reported in Luna et al. (2022) for the CO ice refractive index and density measured at 20 K deposition temperature, respectively n = 1.30 and ρ = 0.876 g cm−3.
5 ASTROPHYSICAL IMPLICATIONS
The CO ice density values obtained in this work are in line with those recently reported by Luna et al. (2022). Moreover, we observed a decrease of the density at deposition temperatures below 13 K. This behaviour of the density reminds that of colour in analogue CO ice experiments, where the colour temperature increases in the same deposition temperature range. Eye observations see a brownish colour at 8 K that becomes gradually less intense up to 13 K. At higher deposition temperatures, the CO ice is translucent and becomes almost transparent when the temperature approaches the thermal desorption of the ice, suggesting that the ice is nearly crystalline (Carrascosa et al. 2021). These colorimetric measurements and the linear drop of the CO photodesorption rate (Öberg et al. 2007; Öberg et al. 2009; Muñoz Caro et al. 2016; Sie et al. 2022) for increasing deposition temperature, might be a manifestation of molecular disorder in CO ice grown below 20 K. If this is correct, CO ice grown at the lowest investigated temperature, around 10 K, presents the highest molecular disorder, and we report here that this CO ice structure corresponds to the lowest ice density.
Jiang et al. (1975) estimated the infrared band strength of CO ice deposited at high pressure compared to modern setups: their deposition rate of 0.5 to 2 μm requires a pressure about 16 to 66 times higher than typical experiments performed at 1 × 10−6 mbar during deposition. To obtain this band strength, Jiang et al. (1975) also adopted a literature value of the CO ice density measured at a relatively high temperature, 30 K (Vegard 1930). According to Luna et al. (2022) and this work, the CO ice density depends on the temperature and pressure during deposition, and therefore, the value of the CO infrared band strength in Jiang et al. (1975) needs a revision. We propose to use |$\mathcal {A}(\rm CO)$| = (8.7 ± 0.5) × 10−18 cm molecule−1 for future column density estimations. This value is valid in the experimental range from 11 to 28 K deposition temperatures investigated in this work, for which no variations of the integrated absorbance area and sticking probability were found (Cazaux et al. 2017). The CO ice column density values reported in previous experimental and observational papers might thus be underestimated, they would be about 23 per cent lower than the actual value. Most of the CO ice column densities reported in the literature adopted a band strength of |$\mathcal {A}(\rm CO)$| = 1.1 × 10−17 cm molecule−1 (Jiang et al. 1975), they would need to be multiplied by a factor of 1.3 for correction. An example is the number of monolayers on the surface, or just beneath the surface of the ice, involved in the photodesorption of CO, i.e. N = 5 × 1015 molecules cm−2 or about 5 monolayers (ML) where 1 ML = 1 × 1015 molecules cm−2 (Muñoz Caro et al. 2010; Fayolle et al. 2011; Chen et al. 2014). After correction, this becomes 6.5 ML. Considering our average density value of CO ice deposited at 11 K, 0.837 g cm−3, and equation (24), it is found that the thickness of one monolayer is 0.56 nm, and 3.36 nm for the top 6.5 ML of ice. The UV photons emitted by the MDHL that are absorbed deeper than 3.36 nm would not lead us to photodesorption of CO molecules.
ACKNOWLEDGEMENTS
This research has been funded by projects PID2020-118974GB-C21, PID2020-118974GB-C22, and MDM-2017-0737 Unidad de Excelencia ‘María de Maeztu’ – Centro de Astrobiología (INTA-CSIC) by the Spanish Ministry of Science and Innovation, and grant No. NSTC 110-2628-008-004-MY4 from Taiwan. The student G. Mettepenningen from TU Delft participated in the preliminary phase of this project.
DATA AVAILABILITY
The data underlying this article cannot be shared publicly.