The revised BSR DMARD guidelines introduced substantial changes to monitoring recommendations for hydroxychloroquine [1]. The guidelines, which reflected the Royal College of Ophthalmologists (RCOphth) 2018 recommendations on retinal monitoring [2], introduced a significant burden on clinical teams, and some services were unable to deliver them. The RCOphth has now published updated guidelines on retinal monitoring for hydroxychloroquine and chloroquine users in the United Kingdom (December 2020) [3]. The revised guidelines should be welcomed by patients, rheumatologists and ophthalmologists. This editorial summarises the key changes to the recommendations that will impact on the clinical practice of rheumatologists and other prescribers of hydroxychloroquine.

The new RCOphth recommendations do not support baseline testing for initiators of hydroxychloroquine and chloroquine. Annual retinal monitoring should begin after 1 year of treatment initiation if additional risk factors for retinal toxicity are present, and after 5 years for all other users (Fig. 1). Additional risk factors include a high dose of hydroxychloroquine (>5mg/kg per day), concurrent tamoxifen use, renal impairment (eGFR <60 ml/min/1.73m2) and chloroquine use [4, 5]. At monitoring visits, it is recommended that all users undergo retinal imaging with optical coherence tomography and fundus autofluorescence imaging. Visual field testing—which is time-consuming and often unreliable [6, 7]—should be used only as a second-line test (Fig. 1).

Hydroxychloroquine retinopathy monitoring algorithm
Fig. 1

Hydroxychloroquine retinopathy monitoring algorithm

Two abnormal test results are required for the diagnosis of hydroxychloroquine retinopathy. ERG: electroretinography; FAF: fundus autofluorescence imaging; SD-OCT: spectral-domain optical coherence tomography.

The new RCOphth recommendations are expected to increase the efficiency and reduce the cost [7] of delivering monitoring services without reducing the overall diagnostic yield. Virtual clinics, in which a patient undergoes retinal imaging tests that are reviewed by a clinician at a later time, are better suited to the new monitoring algorithm. The reduced cost of monitoring should facilitate Clinical Commissioning Groups to fund services and protect hydroxychloroquine users and prescribers. Concerns about the effectiveness of baseline testing and the incomplete coverage of monitoring services highlighted in the British Society for Rheumatology’s statement on retinal monitoring for hydroxychloroquine and chloroquine users [8] (30 March 2020) are in part addressed by the new recommendations.

A review of the RCOphth guideline (2018) [2] was prompted by the publication of additional studies judged to be of sufficient quality and relevance. The literature was systematically evaluated to identify studies relevant to the timing of monitoring and the tests that should be performed; the full methodology is detailed in the published guideline [9]. In particular, two high-quality published audits of hydroxychloroquine retinopathy monitoring services undertaken according to the 2018 recommendations were identified [6, 7]. Marshall et al. identified that of 782 individuals who received a baseline assessment (mean duration of therapy: 1.7 years, s.d. 1.3 years), none were found to have abnormalities that precluded continued use of hydroxychloroquine [6]. Gobbett et al. found that of 345 baseline assessment visits, only 26 individuals were unsuitable for monitoring due to co-existing pathologies (pooled frequency of abnormalities on baseline testing: 2.3% across both studies) [7].

Baseline testing was found to account for over half of all monitoring visits overall, involving the use of significant resources [7]. Furthermore, it is recognised that a significant proportion of hydroxychloroquine initiators will no longer be taking the drug at 5 years due to intolerance or insufficient clinical response. On consideration of these data, the RCOphth guideline development group did not consider the limited clinical benefit of baseline testing to be sufficient to justify the significant resources required to support it.

A large case-control study had identified a prevalence of retinopathy of 7.5% in long-term (>5 years) hydroxychloroquine users in the USA using modern retinal imaging techniques [5]. However, this had not been replicated in other populations. Using the same diagnostic criteria, a prevalence of retinopathy of 6.3% in long-term hydroxychloroquine users was identified in a UK population, a difference that is likely explained by a disparity in risk characteristics between the groups [6]. This study further validated the case for retinal monitoring in the UK [6].

The same two studies identified visual field testing as a source of inefficiency in the monitoring protocol: 33.1% of tests were considered unreliable and 24.9% were of poor quality in one study [6] and 17% were unreliable in the other [7]. Further appointments are needed to repeat visual field tests due to poor reliability, poor quality or to ensure that any possible abnormality consistent with toxicity is repeatable [6]. Indeed, resources may be insufficient to repeat every visual field test [7]. The new RCOphth recommendations will reduce the inefficiency in the monitoring protocol attributed to visual field testing, which is now recommended only for individuals with objective retinal imaging abnormalities consistent with hydroxychloroquine retinopathy. The UK recommendations [3] on monitoring for hydroxychloroquine users now depart significantly from the current US recommendations (2016) on baseline assessments and visual field testing [10]. However, improvements in the efficiency and cost-effectiveness of the monitoring protocol are expected to improve access to monitoring for individuals at risk of sight loss.

Rheumatologists should be aware of the new RCOphth recommendations for retinal monitoring in hydroxychloroquine and chloroquine users as summarised above, which should reduce the risk both for the user and prescriber. The Macular Society, in collaboration with the RCOphth, has produced an updated patient information leaflet, which reflects the new guideline, available at www.macularsociety.org.

Funding: The Medical Research Council UK provides funding to I. H. Y. [grant number MR/R000735/1].

Disclosure statement: None of the authors have any financial interest in a product, method or material or lack thereof.

References

1

Ledingham
J
,
Gullick
N
,
Irving
K
, on behalf of the BSR and BHPR Standards, Guidelines and Audit Working Group et al.
BSR and BHPR guideline for the prescription and monitoring of non-biologic disease-modifying anti-rheumatic drugs
.
Rheumatology (Oxford, England)
2017
;
56
:
865
8
.

2

Yusuf
IH
,
Foot
B
,
Galloway
J
et al.
The Royal College of Ophthalmologists recommendations on screening for hydroxychloroquine and chloroquine users in the United Kingdom: executive summary
.
Eye (London, England)
2018
;
32
:
1168
73
.

3

Yusuf
IH
,
Foot
B
,
Lotery
AJ.
The Royal College of Ophthalmologists recommendations on monitoring for hydroxychloroquine and chloroquine users in the United Kingdom (2020 revision): executive summary
.
Eye (London, England)
2021
. doi: 10.1038/s41433-020-01380-2.

4

Yusuf
IH
,
Sharma
S
,
Luqmani
R
,
Downes
SM.
Hydroxychloroquine retinopathy
.
Eye (London, England)
2017
;
31
:
828
45
.

5

Melles
RB
,
Marmor
MF.
The risk of toxic retinopathy in patients on long-term hydroxychloroquine therapy
.
JAMA ophthalmology
2014
;
132
:
1453
60
.

6

Marshall
E
,
Robertson
M
,
Kam
S
et al.
Prevalence of hydroxychloroquine retinopathy using 2018 Royal College of Ophthalmologists diagnostic criteria
.
Eye (London, England)
2021
;
35
:
358
6
.

7

Gobbett
A
,
Kotagiri
A
,
Bracewell
C
,
Smith
J.
Two years' experience of screening for hydroxychloroquine retinopathy
.
Eye (London, England)
2020
. doi: 10.1038/s41433-020-1028-4.

8

British Society for Rheumatology. Statement: hydroxychloroquine and chloroquine retinopathy screening. https://www.rheumatology.org.uk/News-Policy/Details/Statement-hydroxychloroquine-chloroquine-retinopathy-screening (8 January 2020, date last accessed).

9

Royal College of Ophthalmologists. Hydroxychloroquine and chloroquine retinopathy: recommendations on monitoring. 2020. https://www.rcophth.ac.uk/wp-content/uploads/2020/12/Hydroxychloroquine-and-Chloroquine-Retinopathy-Monitoring-Guideline.pdf (11 January 2021, date last accessed).

10

Marmor
MF
,
Kellner
U
,
Lai
TY
,
Melles
RB
,
Mieler
WF.
Recommendations on screening for chloroquine and hydroxychloroquine retinopathy (2016 revision)
.
Ophthalmology
2016
;
123
:
1386
94
.

This article is published and distributed under the terms of the Oxford University Press, Standard Journals Publication Model (https://academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model)

Comments

0 Comments
Submit a comment
You have entered an invalid code
Thank you for submitting a comment on this article. Your comment will be reviewed and published at the journal's discretion. Please check for further notifications by email.